JINLING NEWS
Two Cities Shine Together | Jierxi Cooling Appears at the Shanghai Computing-Power Exhibition and the Guiyang HVAC Annual Conference, Empowering Green and Low-Carbon Cooling with Systematic Solutions

From October 26 to 30, Zhejiang Jinling Refrigeration Engineering Co., Ltd. embarked on a dual-city coordinated journey: exhibiting at the 2026 International Computing-Power Synergy Industry Chain Exhibition in Shanghai while simultaneously appearing at the 25th HVACR Academic Annual Conference in Guiyang. One in the east, one in the west; one exhibition, one conference. Jierxi Cooling closely aligned itself with the two major tracks of computing-power synergy and HVACR, showcasing its cooling tower series products, systematized integrated cooling station solutions, and core variable-flow water equalization technology.

Shanghai | Focusing on Computing-Power Synergy and Demonstrating Strong Cooling Capabilities

The 2026 International Computing-Power Synergy Industry Chain Exhibition, themed “Focusing on Computing-Power Synergy and Promoting Common Development,” directly addressed the pain points of integrated development of computing power and electric power. At the exhibition, Jierxi Cooling presented models of the JNT cross-flow open cooling tower and the JNC cross-flow closed cooling tower. Centering on green data center heat dissipation and system energy efficiency optimization, it held in-depth exchanges with industry peers across the value chain. Building on years of project experience in the computing-power energy sector, Jierxi Cooling has delivered multiple benchmark projects and served premium customers such as LONGi, JinkoSolar, China Mobile, and China Telecom, laying a solid heat dissipation foundation for various computing-power application scenarios with stable and reliable cooling equipment.

Guiyang | Systematic Cooling Station Solution Stands Out

The 25th HVACR Academic Annual Conference was themed “Pooling Synergies, Coexistence of Heating and Cooling.” Centering on the main line of “Efficient Cooling · Green and Low-Carbon,” Jierxi Cooling launched its systematized integrated cooling station solution. As a key cooling terminal in HVAC systems, cooling towers directly determine the overall operating energy efficiency of equipment rooms. The Jierxi Cooling Station is not a simple combination of multiple cooling towers; rather, it integrates cooling towers, water treatment units, pipeline networks and valves, and an intelligent control system, relying on AI algorithms to achieve global regulation. Adopting a plug-and-play integrated design, it addresses five major industry challenges in one stop—thermal performance, energy and water conservation, noise control, water quality maintenance, and efficient O&M—completing the upgrade from “simple equipment stacking” to “intelligent system integration.”

Core Technology | Variable-Flow Four-Stage Water Equalization for Stable Efficiency at Every Stage

In response to complex variable-flow operating conditions in the industry, Jierxi Cooling has independently developed variable-flow four-stage water equalization technology, controlling spray water uniformity at every stage:

Stage 1: Balanced water intake for each individual tower, combined with symmetrical piping and an intelligent flow equalizer, preventing individual towers from overloading or sitting idle;

Stage 2: Controllable water distribution in the distribution tray, supported by symmetrical piping design to ensure sufficient heat exchange across the entire tower;

Stage 3: Uniform water distribution by nozzles, with a layered flow equalization device, avoiding dry zones in the fill under variable-flow conditions;

Stage 4: Balanced spray water over the fill, with variable-flow rotating nozzles combined with an array of high and low guide cylinders, ensuring stable spray coverage and reliable operation.

The four-stage flow equalization provides guarantees at every level, achieving even water distribution and efficient heat exchange even under variable-flow conditions.

Academic Sharing | In-Depth Discussion of Wet-Bulb Temperature Theory

During the annual conference, Chen Liangcai, Dean of the Zhejiang Jinling Research Institute, delivered a themed report titled “Revisiting Wet-Bulb Temperature (from Abstract to Intuitive) + Decoding Cooling Tower Approach > 0 and Its Variations” at the cooling tower special exchange session. Dean Chen Liangcai has long been deeply engaged in the frontline of corporate R&D. This academic sharing fully demonstrated Zhejiang Jinling’s professional expertise in fundamental theory and technical research on cooling towers.

Two cities launched together, one exhibition and one conference. From the frontier of the computing-power synergy industry in Shanghai to the HVAC academic exchange event in Guiyang, Zhejiang Jinling engaged with industry partners through products, complete solutions, and cutting-edge technologies, demonstrating its comprehensive strength from single equipment to integrated systems and from finished-product supply to underlying technology R&D. The exhibition has concluded, but innovation continues. We look forward to joining hands with more industry peers to explore new tracks in efficient cooling and embark on a new journey toward green and low-carbon development!